Parts Lookup    Parts by Category


Sensi Touch Smart Thermostat Manual 1F95U-42WF ST75 NH-AWIFI OH-AWIFI

TM  
SENSI TOUCH SMART THERMOSTAT  
Manual Operation  
Models: 1F95U-42WF series, ST75 series, NH-AWIFI, OH-AWIFI  
Version: January 2020  
©
2020 Emerson Electric Co. All rights reserved  
R-5030  
Table of Contents  
Buttons and Icons  
Basic Functionality  
Menu Settings  
3
4
5
Installation  
10  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
2
BUTTONS AND ICONS  
The Sensi Touch Smart Thermostat can be operated through Wi-Fi using the Sensi app or  
it can be operated at the actual wall unit. Advanced features such as thermostat settings,  
scheduling and email alerts are only available through the Sensi app.  
MENU  
FAN  
Access thermostat configurations.(See page 5 for more details).  
Switches fan mode from Auto or On. Leave the fan mode on  
Auto to allow the thermostat to control the fan as necessary.  
CURRENT ROOM TEMPERATURE  
The room temperature at the thermostat.  
HUMIDITY  
Displays current humidity  
UP ARROW  
Adjusts the temperature set point or thermostat configuration.  
MODE  
Switches system mode between Heat, Cool, Off, Aux or Auto.  
CURRENT SET TEMPERATURE  
Current set temperature the thermostat will maintain.  
TIME  
DIsplays current time.  
DOWN ARROW  
Adjusts the temperature set point or thermostat configuration.  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
3
BASIC FUNCTIONALITY  
Switching system mode  
Press the mode button (see buttons and icons) to  
switch between all available system mode settings.  
When the mode is “Off” the thermostat will not  
bring on your heating or cooling systems.  
Fan mode  
If you want to circulate the indoor blower, you can switch  
fan mode to “On.” Turn the fan back to “Auto” when you want  
the thermostat to control your indoor blower as necessary.  
Leaving the fan in “On” will run your blower continuously.  
Holding one temperature  
If you want to hold one temperature, turn Schedule “Off.” Then,  
adjust the set point using the up and down arrow buttons.  
The thermostat will hold this temperature, in the set system  
mode, until you turn Schedule back “On” or until you adjust  
the set point again using the up and down arrow buttons.  
Temporary hold  
When your Schedule is “On,” your Sensi thermostat  
controls your home based on the time and temperature  
settings in the current schedule. To temporarily change  
your temperature, use the up and down arrows in the app  
or on the thermostat. Your Sensi thermostat will display  
the time it will hold for next to the set temperature. It  
will hold your new temperature until the next scheduled  
set point with a minimum hold time of two hours.  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
4
MENU SETTINGS  
Menu settings  
You can access several settings and options  
about your thermostat in the menu.  
Note: The “Time Setup” sub menu will only be available when Wi-Fi is  
turned “off.”  
Sleep Mode  
You have the option to display the room temperature even when the  
Sensi Touch screen goes to sleep. Simply toggle your selection from  
this menu.  
Back Glow  
This light can be used to help you see your wiring and  
terminals when installing the thermostat on the wall. The  
switch is on the thermostat base. Be sure to turn the light to  
“off” before snapping the thermostat face to the base.  
After installation, you have the option to toggle the back glow on and off  
from the thermostat menu to help light the area near the thermostat.  
Note: The back glow switch on the thermostat base must be in the  
“off” position for this feature to work via the thermostat menu.  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
5
MENU SETTINGS  
Home Screen Content  
Toggle what you want to see on the display from  
this menu. You can display the current time,  
humidity or change from Fahrenheit to Celsius.  
Wi-Fi  
The Sensi app will instruct you how to connect Sensi to  
Wi-Fi. You can also turn Wi-Fi on or off at any time.  
Turn Wi-Fi Off  
If connecting to Wi-Fi is not an option, turn  
off Wi-Fi on the thermostat and manually set  
a time and a schedule from the unit.  
Press Menu.  
Press Wi-Fi.  
Toggle Wi-Fi “Off.”  
Press the back arrow to return to the main screen.  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
6
MENU SETTINGS  
Schedule  
If your Sensi Touch is connected to Wi-Fi, the schedule is  
programmed based on time and temperature set points  
from the Sensi app. If you are not connected to Wi-Fi, you  
can set a basic schedule with 4 points from the unit.  
Setting a schedule on the unit  
Turn Wi-Fi “Off.” (See page X.)  
Go back to the main menu options.  
Select “Schedule.”  
Make sure “Schedule” is toggled “On.”  
Select which day grouping you want to edit: weekdays or weekend.  
Select which set point you want to edit.  
Adjust the set point using the up and down arrows.  
“Save” when you have the set point to your desired time and temperature.  
Use the arrow in the upper left hand corner to return to the set points.  
Continue to edit the set points as you desire.  
Use the arrow in the upper left hand corner to return to “Schedule” screen.  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
7
MENU SETTINGS  
Time setup  
If you have Wi-Fi turned “Off” you will be able to set  
the date and time on the thermostat. If you’re going  
to connect Sensi to Wi-Fi, the date and time will be  
automatically generated based on your time zone.  
Select the date or time to edit them.  
Adjust the date or time using the up and down arrow buttons.  
Press “Save” when you’re done.  
Use the arrow in the upper left hand corner to return to the previous screen.  
About thermostat  
This menu displays a quick glance at your thermostat information.  
It includes your model number, MAC ID (uniquely identifies  
your thermostat), build date, firmware version, technical  
support contact information, and a factory reset button.  
Pressing the factory reset button will change all  
settings back to default (except for the HVAC Equipment  
settings) and clear any HomeKit pairing so someone  
else can connect the Sensi Touch to Wi-Fi.  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
8
MENU SETTINGS  
Advanced Set Up  
Here you can check the HVAC settings, set the Circulating  
Fan feature and adjust your humidification settings,  
if you have an accessory installed. (Humidification  
set up is recommended for a contractor only.)  
Circulating Fan  
Here you can set the Circulating Fan Feature. If you want to  
circulate the air in your home using your indoor blower fan,  
you can set this feature in the app or at the thermostat. A  
percentage is selected to indicate how often the fan should  
run each hour, You can set 5% increments from 10% – 100%.  
EXAMPLE:  
If you set the Circulating Fan to 50%, the fan  
will run 30 minutes every hour.  
If any heat/cool cycles occur during the hour, their  
runtime is subtracted from the overall fan run time.  
Setting the feature from the  
thermostat:  
1. Press Menu  
2. Press Advanced Setup  
3. Press Fan Mode Options  
4. Toggle Circulating Fan on  
5. Use the up or down arrow button to set the percentage  
you want the fan to run per hour  
6. Press the back arrow button until you’re back at the main screen  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
9
INSTALLATION  
Set up HVAC equipment  
This allows you to change a series of settings to customize the thermostat for your specific  
system. Refer to the chart below for a complete listing of thermostat configurations and what  
they stand for. If you are installing the thermostat on the wall for the first time, we highly  
recommend that you download the Sensi app and follow the installation instructions.  
However, if you are experiencing an issue or you want to check your system configurations, you  
can manually configure your thermostat as well. Learn more about how to properly configure your  
thermostat by searching “configure” on our support site at sensi.emerson.com/en-us/support.  
CONFIGURATION MENU ITEMS REFERENCE  
Menu item  
Sleep Mode  
Backglow  
Default  
Off  
Options  
Turn sleep display mode on/off  
Off / On  
Off  
On  
Indoor Humidity  
Home Screen Content  
On  
Time of Day  
°
-
-
-
F
°F / °C  
Schedule  
5 / 2 Day Schedule  
Wi-Fi  
Connect to Wi-Fi  
About Thermostat  
Advanced Setup  
Model Number/Reset  
HVAC Equipment | Fan Mode Options  
Outdoor Setup AC1/AC2/HP1/HP2/None  
Indoor Setup GA1/GA2/EL1/EL2/Fan  
Reversing Valve Position O/B/6/None  
Additional Accessories None/Add  
Humidifier (wired to thermostat) Yes/No  
Dehumidifier (wired to thermostat) Yes/No  
AC2  
EL2  
O
Set Up HVAC Equipment  
None  
No  
No  
Circulating Fan Off/On  
Fan Mode Options  
Humidify  
Off  
1
0% - 100% (5% increments)  
Off  
Humidification Off/On  
5%- 50% (5% increments)  
4
0%  
Off  
0%  
Dehumidification Off/On  
40% - 95% (5% increments)  
Dehumidify  
5
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
10  
INSTALLATION  
See below for definitions of the wiring terminals on the sub-base of the thermostat.  
Terminal outputs and wiring diagrams  
TERMINAL LABEL  
DEFINITION  
RH*  
RC*  
C**  
G
Power for heating, 24V  
Power for cooling, 24V  
Common wire, 24V  
Indoor blower (fan)  
Y
First outdoor stage cooling on conventional systems or first heat and cool on heat pump systems  
Second outdoor stage cooling on conventional systems or second heat and  
cool on two stage heat pump systems or humidifier  
Y2/*  
W/E  
First indoor stage heat on conventional systems or first stage auxiliary/emergency heat on heat pump systems  
Second indoor stage heat on conventional systems or second stage auxiliary/  
emergency heat on heat pump systems or dehumidifier  
W2/*  
O/B  
L
Changeover (reverse valve) connection for heat pump or zone panel systems  
Heat Pump system, “L” wire connection  
*
If the old thermostat has separate RC and RH wires coming out of the wall, clip the RC/  
RH jumper on the back of the thermostat above the battery compartment.  
*
*The common wire could be labeled “C” on your old thermostat, or it could be labeled “B”  
or “X.” Please refer to the owner’s manual of your old thermostat for clarification.  
Does Wire Color Correspond to the Thermostat  
Terminals?  
Wire color does not always correspond to the thermostat letters. A white wire may be attached to the “W” terminal  
on the old thermostat, or it may be attached to a different terminal with a different letter. Be sure to take a photo  
of the old thermostat that shows the wire colors and terminal letters before labeling and removing any wires.  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
11  
INSTALLATION  
Thermostat base  
BACK GLOW SWITCH  
RH/RC JUMPER  
Switching this “On” illuminates the thermostat base. Make  
sure you switch this to “Off” after installation so you can  
still operate this feature from the thermostat display.  
Only clip this if you have separate RH and RC wires coming  
out of the wall. This indicates a two-transformer system.  
Sensi Touch Smart Thermostat | MANUAL OPERATION GUIDE  
12  
Privacy Policy       |       Contact       |        Terms and Disclosure       |        About

Youtube Small Engine Parts
© 2009 - 2024 Barrett Small Engine